Ingredients

CALL MD AT ONCE. KEEP AWAY FROM HEAT, SPKS & OPEN

RTECS: 9999999ZZ


ADEQUATE VENTILATION. FOR INDUSTRIAL USE ONLY. KEEP

RTECS: 9999999ZZ


BUTENE, POLYMERS; (BUTENE, HOMOPOLYMER)

CAS: 9003-29-6

RTECS: EM9032000

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


HEPTANE

CAS: 142-82-5

RTECS: MI7700000

Fraction By Weight: 14%

OSHA PEL 500 PPM

ACGIH TLV: 400 PPM/500STEL


CLAY (KAOLIN); (KAOLIN)

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: >3%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST


CALCIUM CARBONATE; (LIMESTONE)

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: >3%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


BUTYL RUBBER; (CROSS LINKED BUTYL RUBBER)

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


TIMES 100 TO DETERM SPILL QTY OF PROD THAT TRIGGERS

RTECS: 9999999ZZ


NATIONAL RESPONSE CENTER (1-800-424-8802).

RTECS: 9999999ZZ


15 MIN. VAP IS HARMFUL IF INHALED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE MODERATE
IRRITATION. SKIN:PROLONGED OR REPEATED CONTACT MAY CAUSE
DERMATITIS. ABSORPTION THROUGH INTACT SKIN MAY CONTRIBUTE TO
OVERALL EXPOSURE. MAY CAUSE DRYING. INHALATION:MAY C AUSE CENTRAL
NERVOUS SYSTEM DEPRESSION (NARCOSIS) CHARACTERIZED BY HEADACHE,
DIZZINESS, MUSCULAR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:WEAKNESS AND FATIGUE. MAY CAUSE
UNCONSCIOUSNESS IF EXPOSURE IS EXCESSIVE. INGESTION:CAUSES CHEMICAL
PNEUMONITIS IF ASPIRATED INTO LUNGS. MAY CAUSE CNS DEPRESS
(NARCOSIS) CHARACT BY HDCH, DIZ Z, MUSCULAR WEAK & FATG. CHRONIC:
HUMANS:MAY CAUSE NEUROMUSCULAR DMG. ANIMAL:MAY CAUSE PSYCHOLOGICAL
DISORDERS.
Medical Cond Aggravated by Exposure:NOT APPLICABLE.

First Aid

First Aid:EYE CONTACT:FLUSH EYES WITH WATER FOR AT LEAST 15 MINUTES.
SKIN CONTACT:WASH WITH HAND CLEANER, THEN SOAP AND WATER.
INHALATION:REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED BEGIN
ARTIFICIAL RESPIRATI ON; CALL A DOCTOR. INGESTION:DO NOT INDUCE
VOMITING; CALL A DOCTOR AT ONCE. SPECIAL INSTRUCTIONS TO
PHYSICIAN:NOT APPLICABLE.

Fire Fighting

Flash Point Method:TCC
Flash Point:14F,-10C
Lower Limits:1%
Upper Limits:7%
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL, NFPA CLASS B
EXTINGUISHER.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER SPRAY MAY BE INEFTIVE, BUT MAY BE USED TO COOL
CLSD CNTNRS. IF WATER IS USED, USE FOG NOZZS.
Unusual Fire/Explosion Hazard:MAY FORM COMBUST &/OR EXPLO MIX W/AIR.
CLSD CNTNRS MAY EXPLODE IF EXPOSED TO EXTREME HEAT. VAPS MAY TRAVEL
CONSIDERABLE DIST TO IGNIT SOURCE & FLASH BACK.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT, AVOID BRTHG VAP,
VENT AREA. REMOVE W/NON SPKING TOOLS TO SAFE AREA FREE FROM IGNIT
SOURCES. EXPOSE MATL TO AIR UNTIL SOLID. NOTIFICATION TO NATNL
RESPONSE CTR (NRC) OF REL OF PROD IS REQ BY SUPERFUND AMENDMENTS&
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE ONLY IN
CLOSED CONTAINERS, IN WELL VENTILATED LOCATION, AWAY FROM SPARKS,
FLAMES AND OTHER IGNITION SOURCES.
Other Precautions:CNTNRS SHOULD BE GROUNDED WHEN POURING. AVOID FREE
FALL OF LIQ. DO NOT FLAME CUT, BRAZE/WELD. PRECAUTIONARY
LBLING:WATER BLOCK SEAL S-20. WARNING! EXTREMELY FLAM. CNTNS PETROL
DISTILS. AVOID CONT W/SK IN/EYES; FLUSH THORO W/WATER FOR (ING 8)

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR FOR PROTECTION
AGAINST ORGANIC VAPORS; DUSTS AND MISTS IF EXPOSURE MIGHT EXCEED
THE TLV.
Ventilation:USE IN A WELL-VENTILATED LOCATION.
Protective Gloves:WEAR NITRILE/POLYVINL ALCOHOL GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . NONE REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC:REAUTHORIZATION ACT OF 1986 (SARA) TITLE III, SECTION 304
UNDER 49 CFR 355 FOR GIVEN RQ'S. THRESHOLD PLANNING QTY (TPQ) IS
SHOWN FOR CHEMS WHICH HAVE BEEN DESIGNATED AS EXTREMELY HAZ SUBSTA
NCE (EHS) UNDER SARA TITLE III, SECTIONS 302/303, & MAY BE
REPORTABLE. (NOTE:EACH RQ SHOULD BE DIVIDED BY WT % (ING 6)

Chemical Properties

Boiling Pt:B.P. Text:200F,93C
Vapor Pres:45 @ 20C
Vapor Density:3.4
Spec Gravity:1.33 (H*2O=1)
Evaporation Rate & Reference:4.5 (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:GRAY PASTE WITH MILD SOLVENT ODOR.
Percent Volatiles by Volume:25.5

Stability

Stability Indicator/Materials to Avoid:YES
KEEP AWAY FROM STRONG OXIDIZERS.
Stability Condition to Avoid:HEAT, SPKS, & OPEN FLAMES; IGNIT SOURCES.
VAPS ARE HVR/AIR & MAY TRAVEL CONSIDERABLE DIST TO IGNIT SOURCE &
FLASH BACK.
Hazardous Decomposition Products:NOT APPLICABLE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . OBSERVE LOCAL REGULATIONS. DO NOT INCINERATE IN
CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.